• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
The Egyptian Journal of Hospital Medicine
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 99 (2025)
Volume Volume 98 (2025)
Volume Volume 100 (2025)
Volume Volume 97 (2024)
Volume Volume 96 (2024)
Volume Volume 95 (2024)
Volume Volume 94 (2024)
Volume Volume 93 (2023)
Volume Volume 92 (2023)
Volume Volume 91 (2023)
Volume Volume 90 (2023)
Volume Volume 89 (2022)
Volume Volume 88 (2022)
Volume Volume 87 (2022)
Volume Volume 86 (2022)
Volume Volume 85 (2021)
Volume Volume 84 (2021)
Volume Volume 83 (2021)
Volume Volume 82 (2021)
Volume Volume 81 (2020)
Volume Volume 80 (2020)
Volume Volume 79 (2020)
Volume Volume 78 (2020)
Volume Volume 77 (2019)
Volume Volume 76 (2019)
Volume Volume 75 (2019)
Volume Volume 74 (2019)
Volume Volume 73 (2018)
Volume Volume 72 (2018)
Volume Volume 71 (2018)
Issue Issue 1
Issue Issue 2
Issue Issue 3
Issue Issue 4
Issue Issue 5
Issue Issue 6
Issue Issue 7
Volume Volume 70 (2018)
Volume Volume 69 (2017)
Volume Volume 68 (2017)
Volume Volume 67 (2017)
Volume Volume 66 (2017)
Volume Volume 65 (2016)
Volume Volume 64 (2016)
Volume Volume 63 (2016)
Volume Volume 62 (2016)
Volume Volume 61 (2015)
Volume Volume 60 (2015)
Volume Volume 59 (2015)
Volume Volume 58 (2015)
Volume Volume 57 (2014)
Volume Volume 56 (2014)
Volume Volume 55 (2014)
Volume Volume 54 (2014)
Volume Volume 53 (2013)
Volume Volume 52 (2013)
Volume Volume 51 (2013)
Volume Volume 50 (2013)
Volume Volume 49 (2012)
Volume Volume 48 (2012)
Volume Volume 47 (2012)
Volume Volume 46 (2012)
Volume Volume 45 (2011)
Volume Volume 44 (2011)
Volume Volume 43 (2011)
Volume Volume 42 (2011)
Volume Volume 41 (2010)
Volume Volume 40 (2010)
Volume Volume 39 (2010)
Volume Volume 38 (2010)
Volume Volume 37 (2009)
Volume Volume 36 (2009)
Volume Volume 35 (2009)
Volume Volume 34 (2009)
Volume Volume 33 (2008)
Volume Volume 32 (2008)
Volume Volume 31 (2008)
Volume Volume 30 (2008)
Volume Volume 29 (2007)
Volume Volume 28 (2007)
Volume Volume 27 (2007)
Volume Volume 26 (2007)
Volume Volume 25 (2006)
Volume Volume 24 (2006)
Volume Volume 23 (2006)
Volume Volume 22 (2006)
Volume Volume 21 (2005)
Volume Volume 20 (2005)
Volume Volume 19 (2005)
Volume Volume 18 (2005)
Volume Volume 17 (2004)
Volume Volume 16 (2004)
Volume Volume 15 (2004)
Volume Volume 14 (2004)
Volume Volume 13 (2003)
Volume Volume 12 (2003)
Volume Volume 11 (2003)
Volume Volume 10 (2003)
Volume Volume 9 (2002)
Volume Volume 8 (2002)
Volume Volume 7 (2002)
Volume Volume 6 (2002)
Volume Volume 5 (2001)
Volume Volume 4 (2001)
Volume Volume 3 (2001)
Volume Volume 2 (2001)
Volume Volume 1 (2000)
Bassem Fayez Aziz Riad, George Adel Aziz Mansour, A. (2018). Study of Accuracy of Corneal Flap Thickness by Using Femtosecond Laser Technology. The Egyptian Journal of Hospital Medicine, 71(3), 2775-2779.
Ahmed Hassan Samir Assaf, Rania Gamal Eldin Zaky, Bassem Fayez Aziz Riad, George Adel Aziz Mansour. "Study of Accuracy of Corneal Flap Thickness by Using Femtosecond Laser Technology". The Egyptian Journal of Hospital Medicine, 71, 3, 2018, 2775-2779.
Bassem Fayez Aziz Riad, George Adel Aziz Mansour, A. (2018). 'Study of Accuracy of Corneal Flap Thickness by Using Femtosecond Laser Technology', The Egyptian Journal of Hospital Medicine, 71(3), pp. 2775-2779.
Bassem Fayez Aziz Riad, George Adel Aziz Mansour, A. Study of Accuracy of Corneal Flap Thickness by Using Femtosecond Laser Technology. The Egyptian Journal of Hospital Medicine, 2018; 71(3): 2775-2779.

Study of Accuracy of Corneal Flap Thickness by Using Femtosecond Laser Technology

Article 22, Volume 71, Issue 3, April 2018, Page 2775-2779  XML PDF (240.64 K)
Document Type: Original Article
View on SCiNiTO View on SCiNiTO
Author
Ahmed Hassan Samir Assaf, Rania Gamal Eldin Zaky, Bassem Fayez Aziz Riad, George Adel Aziz Mansour
Department of Ophthalmology School of Medicine, Ain Shams University, Cairo (Egypt)
Abstract
Background- LASIK is the most popular surgery to correct the refractive errors nowadays. It is proved to be safe, effective and well predictable. It is important to produce a uniform flap with a narrow SD from the intended thickness. The Integrated optical pachymetry is a convenient and useful feature of the EX500 excimer laser which can be used to measure flap thickness intraoperatively.Objectives: this study aimed to detect the accuracy of Allegretto Wavelight FS200™ platform in creation of different corneal flap thicknesses. Patients and Methods:  sixty eyes of 30 myopic patients were included in our study, the patients were operated by 2 different surgeons from June 2017 till December 2017. The patients were distributed randomly into 3 studied groups. Group I (20 eyes with intended fs flap 100um), group II (20 eyes with intended fs flap 110um) and group III (20 eyes with intended fs flap 120um). All participants were subjected to full medical history taking, uncorrected distance visual acuity, slit-lamp microscopy, corneal topography using oculus® pentacam device, manifest and cycloplegic refraction, corrected distance visual acuity, fundus bio-microscopy examination using 90 D lens. 
Results: inthis study 100μm thickness group (Group A) showed the lowest difference between the mean result and the intended flap (-0.35um) followed by the 120um group (Group C) with difference of (-2.9um) between the mean result and the intended flap thickness followed by the 110μm group (group B) with the highest difference (-3.45um) from the intended flap thickness.
Conclusion: the flaps made with the Wavelight FS200 femtosecond laser were predictable and uniform more predictable in group A than in group C and B, but with no statistical significance between the three studied groups (P=0.402).
Keywords
femtosecond laser; LASIK; allegretto Favelight FS200TM; EX500 optical pachymetry
Statistics
Article View: 174
PDF Download: 338
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.